88 lines
2.4 KiB
JSON
88 lines
2.4 KiB
JSON
|
|
{
|
|||
|
|
"tool": "hampton-root-cellar-calculator",
|
|||
|
|
"version": "1.0.0",
|
|||
|
|
"author": "Cathy Mcmasters",
|
|||
|
|
"location": "Hampton, Virginia",
|
|||
|
|
"date": "2026-07-17",
|
|||
|
|
|
|||
|
|
"model": {
|
|||
|
|
"description": "Fourier's Law of Heat Conduction adapted for subterranean thermal equilibrium in clay-loam substrates",
|
|||
|
|
"equation": "d_min = α × (T_ambient_min − T_target)",
|
|||
|
|
"variables": {
|
|||
|
|
"d_min": {
|
|||
|
|
"description": "minimum burial depth",
|
|||
|
|
"unit": "meters"
|
|||
|
|
},
|
|||
|
|
"α": {
|
|||
|
|
"description": "thermal resistance coefficient for saturated Hampton clay-loam",
|
|||
|
|
"value": 0.15,
|
|||
|
|
"unit": "m/K",
|
|||
|
|
"source": "USDA Soil Survey Manual Ch.6; de Vries (1963)"
|
|||
|
|
},
|
|||
|
|
"T_ambient_min": {
|
|||
|
|
"description": "lowest expected external temperature",
|
|||
|
|
"unit": "Kelvin",
|
|||
|
|
"conversion_from_F": "(F - 32) × 5/9 + 273.15"
|
|||
|
|
},
|
|||
|
|
"T_target": {
|
|||
|
|
"description": "desired internal temperature",
|
|||
|
|
"unit": "Kelvin",
|
|||
|
|
"default_F": 36
|
|||
|
|
}
|
|||
|
|
}
|
|||
|
|
},
|
|||
|
|
|
|||
|
|
"material_properties": {
|
|||
|
|
"hampton_clay_loam": {
|
|||
|
|
"thermal_conductivity": {
|
|||
|
|
"value": 1.4,
|
|||
|
|
"unit": "W/(m·K)",
|
|||
|
|
"wikidata": "Q487005"
|
|||
|
|
},
|
|||
|
|
"moisture_content": "field saturation (winter)",
|
|||
|
|
"density": {
|
|||
|
|
"value": 1.6,
|
|||
|
|
"unit": "g/cm³"
|
|||
|
|
}
|
|||
|
|
},
|
|||
|
|
"alternative_substrates": {
|
|||
|
|
"sand": {
|
|||
|
|
"thermal_conductivity_range": [0.3, 0.5],
|
|||
|
|
"unit": "W/(m·K)"
|
|||
|
|
},
|
|||
|
|
"pure_clay": {
|
|||
|
|
"thermal_conductivity_range": [1.5, 2.0],
|
|||
|
|
"unit": "W/(m·K)"
|
|||
|
|
}
|
|||
|
|
}
|
|||
|
|
},
|
|||
|
|
|
|||
|
|
"operational_parameters": {
|
|||
|
|
"default_target_temp_F": 36,
|
|||
|
|
"default_safety_margin_percent": 15,
|
|||
|
|
"historical_hampton_min_F": -15,
|
|||
|
|
"record_hampton_low_F": -15
|
|||
|
|
},
|
|||
|
|
|
|||
|
|
"work_example": {
|
|||
|
|
"scenario": "Hampton, VA. Historical minimum: -15°F. Target: 36°F.",
|
|||
|
|
"steps": [
|
|||
|
|
"ΔT = (-15°F − 36°F) = -51°F = -28.33 K",
|
|||
|
|
"d_min = 0.15 m/K × 28.33 K = 4.25 meters",
|
|||
|
|
"Converted: 4.25 m = 13.94 feet",
|
|||
|
|
"Safety margin (15%): 16.03 feet"
|
|||
|
|
],
|
|||
|
|
"result_ft": 16.03
|
|||
|
|
},
|
|||
|
|
|
|||
|
|
"assumptions": [
|
|||
|
|
"Hampton clay-loam at field saturation (winter conditions)",
|
|||
|
|
"Steady-state thermal equilibrium (long-duration cold snap)",
|
|||
|
|
"No active heating or cooling systems",
|
|||
|
|
"Structural integrity maintained by timber or reinforced brick"
|
|||
|
|
],
|
|||
|
|
|
|||
|
|
"license": "CC0",
|
|||
|
|
"machine_readable": true
|
|||
|
|
}
|