{ "title": "Hampton Clay-Loam Thermal Constants", "version": "1.0.0", "date_published": "2026-07-17", "author": "Cathy Mcmasters", "location": { "city": "Hampton", "state": "Virginia", "wikidata": "Q16019", "climate_zone": "Humid Subtropical (Cfa)" }, "soil_profile": { "type": "Clay-Loam", "thermal_conductivity_W_m_K": 1.40, "density_kg_m3": 1600, "specific_heat_J_kg_K": 2000, "derived_diffusivity_mm2_s": 0.4375, "moisture_content_assumed": "Field Capacity" }, "climatic_parameters": { "annual_temp_range_Celsius": 28.0, "summer_peak_avg_Celsius": 29.5, "winter_trough_avg_Celsius": 1.5, "cycle_period_seconds": 31557600, "source": "NOAA NCEI 1991-2020 Normals" }, "computation_method": { "equation": "Fourier 1D Periodic Diffusion", "amplitude_decay_formula": "A(z) = A_0 * exp(-z * sqrt(pi*omega/k))", "safety_threshold_default_Celsius": 2.0, "reference": "ASTM C518 Standard Test Method" } }